ZN63(VS1)-12KV Embedded Poles Type Indoor HV VCB

ZN63(VS1)-12KV Embedded Poles Type Indoor HV VCB
Product Detailed
1)No.1 Vacuum circuit breaker factory 2)Export to Ethiopia,Thailand,Burma,Mongolia,HK,Kenya 3)23 years' manufacture experienc

ZN63(VS1)-12KV Series Embedded Poles Type Indoor HV Vacuum Circuit Breaker

ZN63(VS1)-12 Series Embedded Poles Type Indoor HV Vacuum Circuit Breaker, adopt solid insulation structure, use of advanced solid epoxy sealing technology, the first time, the vacuum interrupter. A leading electrical circuit. insulation and other support to become an integrated combination of solid seal pole. Successfully from a fundamental solution of the vacuum breaker gas environment, tolerance issues, make it more broad. Integrated solid-pole closure of the fluent use of a self-ventilation technology, cleverly solved the structure of solid insulation caused by heat dissipation.

ZN63(VS1)-12 Series Embedded Poles Type Indoor HV Vacuum Circuit Breaker is the first to achieve maintenance-free concept of a circuit breaker. Its high-life vacuum interrupter chamber as well as solid cast epoxy sealing technology applications to ensure an integrated solid-pole sealed maintenance-free, with high reliability using permanent magnetic actuator of the actuator to ensure maintenance-free, electronic control parts reject the traditional auxiliary switch and replaced by photoelectric proximity switches, and use the whole power and intelligent electronic control unit ensures that electronically controlled part of the maintenance-free.

The use of environmental conditions:

1.Ambient temperature: not higher than +40 °C, not less than -15°C(at -30 °C to allow storage and transportation).

2. Altitude: not exceed 1000m.

3. Relative humidity: daily average of not more than 90%, month average of not more than 90%.

saturated vapor pressure daily average of not more than 2.2 × 10-3MPa, month average not more than 1.8 × 10-3MPa.

4. Earthquake intensity: not more than eight.

5. No fire, explosion hazard, serious filthy, chemical corrosion, as well as places of intense vibration.

Mainly technical parameters
 
NOItemUnitsparameters
1Rated voltageKV12
2Rated insulation levelRated Lightning Impulse voltage toleranceKV75
1min Frequency voltage42
3Rated short-circuit breaking currentKA20/2531.540
4        Rated currentA630 630  12501250  1600
12501600 20002000 2500
 2500 3150 3150  4000 
5Rated thermal stability of current (RMS)KA20/2531.540
6Dynamic Stability rated current (peak)6380100
7Rated short-circuit closing current (peak)6380100
8Rated short-circuit breaking current breaking number times50
9Frequency tolerance of the secondary circuit voltage (1min)V2000
10Rated operating sequence 0-0.3s-CO-180s-CO
 0-180s-CO-180s-CO(40kA)
11Rated thermal stabilization timeS4
12Rated a single / back-to-back electric current breaking device group 630/400  800/400(40KA)
13Mechanical lifeTimes10000

   

ZN63(VS1)-12KV Embedded Poles Type Indoor HV VCB